Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Clin. transl. oncol. (Print) ; 25(4): 912-932, abr. 2023. ilus, tab
Artigo em Inglês | IBECS | ID: ibc-217751

RESUMO

The present document includes consensus-based recommendations from the Brachytherapy Group (GEB) of the Spanish Society of Radiation Oncology (SEOR) and the Spanish Society of Medical Physics (SEFM) for interstitial high-dose-rate (HDR) brachytherapy (BT) for gynaecologic malignancies. A nine-item survey—which included questions on experience with interstitial BT; indications and technique; applicator type; magnetic resonance imaging (MRI)-based planning; dose; fractionation schedule; and treatment planning—was sent to all radiation oncology departments (n = 174) in Spain in 2021. Responses were received from 36 centres (50% of all centres [n = 72] with a BT unit). The consensus-based recommendations presented here are based on a review of the available literature, professional experience among the group of experts, and in-person discussions held during the annual meeting of these two societies. We describe the results of the survey and the following: indications; contraindications; patient selection; description of applicators; role of imaging in planning; contouring; dose prescription; dosimetric reconstruction; optimisation; and dose indications for cancers of the cervix, vagina, and vulva. The various clinical scenarios in which interstitial BT is used in the treatment of gynaecological tumours are described in detail, including cervix intracavitary/interstitial hybrid HDR-BT; cervix perineal templates/freehand implants; primary vaginal malignancies/vaginal recurrences; and vulvar interstitial implants (AU)


Assuntos
Humanos , Feminino , Braquiterapia/métodos , Neoplasias dos Genitais Femininos/radioterapia , Dosagem Radioterapêutica , Protocolos Antineoplásicos , Sociedades Médicas , Espanha
3.
Clin Transl Oncol ; 25(4): 912-932, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36445642

RESUMO

The present document includes consensus-based recommendations from the Brachytherapy Group (GEB) of the Spanish Society of Radiation Oncology (SEOR) and the Spanish Society of Medical Physics (SEFM) for interstitial high-dose-rate (HDR) brachytherapy (BT) for gynaecologic malignancies. A nine-item survey-which included questions on experience with interstitial BT; indications and technique; applicator type; magnetic resonance imaging (MRI)-based planning; dose; fractionation schedule; and treatment planning-was sent to all radiation oncology departments (n = 174) in Spain in 2021. Responses were received from 36 centres (50% of all centres [n = 72] with a BT unit). The consensus-based recommendations presented here are based on a review of the available literature, professional experience among the group of experts, and in-person discussions held during the annual meeting of these two societies. We describe the results of the survey and the following: indications; contraindications; patient selection; description of applicators; role of imaging in planning; contouring; dose prescription; dosimetric reconstruction; optimisation; and dose indications for cancers of the cervix, vagina, and vulva. The various clinical scenarios in which interstitial BT is used in the treatment of gynaecological tumours are described in detail, including cervix intracavitary/interstitial hybrid HDR-BT; cervix perineal templates/freehand implants; primary vaginal malignancies/vaginal recurrences; and vulvar interstitial implants.


Assuntos
Braquiterapia , Neoplasias dos Genitais Femininos , Radioterapia (Especialidade) , Neoplasias do Colo do Útero , Neoplasias Vaginais , Feminino , Humanos , Neoplasias dos Genitais Femininos/radioterapia , Braquiterapia/métodos , Dosagem Radioterapêutica , Física , Planejamento da Radioterapia Assistida por Computador/métodos
4.
J Contemp Brachytherapy ; 8(5): 404-414, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27895682

RESUMO

PURPOSE: To study outcome and toxicity in 59 patients with locally advanced cervix carcinoma treated with computed tomography (CT)-based Martinez universal perineal interstitial template (MUPIT) and the new magnetic resonance imaging (MRI)-compatible template Benidorm (TB). MATERIAL AND METHODS: From December 2005 to October 2015, we retrospectively analyzed 34 patients treated with MUPIT and 25 treated with the TB. Six 4 Gy fractions were prescribed to the clinical target volume (CTV) combined with external beam radiotherapy (EBRT). The organs at risk (OARs) and the CTV were delineated by CT scan in the MUPIT implants and by MRI in the TB implants. Dosimetry was CT-based for MUPIT and exclusively MRI-based for TB. Dose values were biologically normalized to equivalent doses in 2 Gy fractions (EQD2). RESULTS: Median CTV volumes were 163.5 cm3 for CT-based MUPIT (range 81.8-329.4 cm3) and 91.9 cm3 for MRI-based TB (range 26.2-161 cm3). Median D90 CTV (EBRT + BT) was 75.8 Gy for CT-based MUPIT (range 69-82 Gy) and 78.6 Gy for MRI-based TB (range 62.5-84.2 Gy). Median D2cm3 for the rectum was 75.3 Gy for CT-based MUPIT (range 69.8-132.1 Gy) and 69.9 Gy for MRI-based TB (range 58.3-83.7 Gy). Median D2cm3 for the bladder was 79.8 Gy for CT-based MUPIT (range 71.2-121.1 Gy) and 77.1 Gy for MRI-based TB (range 60.5-90.8 Gy). Local control (LC) was 88%. Overall survival (OS), disease free survival (DFS), and LC were not statistically significant in either group. Patients treated with CT-based MUPIT had a significantly higher percentage of rectal bleeding G3 (p = 0.040) than those treated with MRI-based TB, 13% vs. 2%. CONCLUSIONS: Template Benidorm treatment using MRI-based dosimetry provides advantages of MRI volume definition, and allows definition of smaller volumes that result in statistically significant decreased rectal toxicity compared to that seen with CT-based MUPIT treatment.

5.
J Contemp Brachytherapy ; 7(4): 265-72, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26622229

RESUMO

PURPOSE: To describe the potential clinical use of a new brachytherapy applicator for gynecological tumors, with special attention to locally advanced cervical carcinoma. This device allows the combination of intracavitary radiotherapy and MRI-compatible transperineal interstitial needles. The design of this template addresses the disadvantages of currently commercially available templates: the inability of the intracavitary component to reach deep into the cervix (MUPIT), and the MRI-incompatibility of these templates (MUPIT and Syed), which necessitates use of CT imaging for the dosimetry. MATERIAL AND METHODS: The newly developed Benidorm Template applicator allows titanium needles in a template with straight and angled holes to provide different angles of divergence to be used with currently existing MRI-compatible intrauterine tubes. It can provide total coverage of the craniocaudal and lateral extension of the tumor (intrautherus, parametrial, and paravaginal). This method is mainly indicated in advanced cervical carcinoma with bulky parametrial invasion (medial or distal), with bulky primary disease that responds poorly to external beam radiotherapy extensive paravaginal involvement (tumor thickness greater than 0.5 cm) extending to the middle or lower third of the vagina, or for disease that has invaded the bladder or rectum (stage IVA). RESULTS: Between April 2013 until December 2014, we treated 15 patients with locally advanced cervical carcinoma employing the Benidorm Template. The median dose at D90 for the CTV was 79.8 Gy (71.5-89.9 Gy), at D2cc for the bladder it was 77.6 Gy (69.8-90.8 Gy), and at D2cc for the rectum it was 71.9 Gy (58.3-83.7 Gy). Values expressed in EQD2, assuming α/ß of 10 for CTV and 3 for OAR. CONCLUSIONS: This new applicator allows the use of MRI-based dosimetry, thus providing the advantages of MRI volume definition. As such, it facilitates determination of complete intracavitary and interstitial CTV coverage and the sparing of normal tissues.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...